نموذج: CA35T
علامة تجارية: براندو
Power: Solenoid
Connection Type: Threaded
Structure: Diaphragm
Valve Type: Right Angle
Voltage: AC24V, AC110V, AC220V, DC24V
Media: Air
Port Size: G1-1/4''
Aperture Of Flow Retea: 35mm
Pressure: 0.3~0.8Mpa
Temperature: -5℃ - 55℃
تفاصيل التعبئة والتغليف: الصناديق والكرتون والمنصات
إنتاجية: 100000pcs per month
نقل: Ocean,Land,Air
مكان المنشأ: نينغو ، الصين
الدعم: 100000pcs per month
الشهادات: CE.ISO
ميناء: Ningbo,Shanghai,Guangzhou
الدفع نوع: L/C,T/T,Paypal
إنكوترم: FOB,CFR,CIF
CA35T صمام مجمع الغبار المربوطة صمام
CA35T GOYEN TYPE TYPE COMBLECTOR PULSE PULSE PULSE تلعب دورًا مهمًا في SYSTERM COMSTERM PULSE JET. إنها سلسلة الزاوية الصحيح 't'. لدينا أيضًا نوع اتصال آخر ، مثل نوع الزاوية الصحيح مع نوع Dresser Nut 'DD' ، ونوع Mm mb -mount "ونوع" FS ".
يستخدم صمام إزالة غبار النبض مكبسًا من الفولاذ المقاوم للصدأ ، وهو مقاوم للضغط ومقاوم للارتداء ، وله عمر خدمة ملايين المرات. إنه "مفتاح" هواء مضغوط لإزالة غبار حقيبة النبض ونظام النفخ في كيس الغبار ، ويتلقى إشارات النبض لضمان أداء جامع الغبار. تقع المقاومة في النطاق المحدد ، مما يضمن قدرة المعالجة وكفاءة الامتصاص لمجمع الغبار.
البيانات الفنية لصمام نبض الملف اللولبي CA 35T :
Model No. | CA35T |
Port Size | G1-1/4'' |
Nornimal Size |
Φ35mm |
Action Type | Pilot Operated |
Valve Type | Right Angle |
Number of Diaphrgam | 1 |
TEMP Range |
-5℃ - 55℃ |
Pressure | 0.3~0.8Mpa |
Seal Material | NBR (common) , all available |
Body Material | Aluminum ADC12 |
تفكيك صمام النبض الكهرومغناطيسي CA35T :
Part Name | Material |
Solenoid Coil | Copper Wire |
Armature Assembly | Stainless Steel |
Spring | Stainless Steel |
Seals & Diaphragm | NBR (common), all available |
Body | Die-casting Aluminum Alloy |
1. تتسرب أو لا تغلق E بسرعة
phenomenon |
Reason |
Solution |
Solenoid Coil Hot |
Solenoid Coil Hot |
Measure whether the coil is energized normally. Check the pulse signal control system to correct incorrect connections |
No power to the coil |
1. Diaphragm rupture 2. The diaphragm surface is dirty and cannot be sealed 3. Hole in blowpipe (submerged) |
1. Repalce Diaphragm 2. Clean diaphragm surface 3. Repair or replace blowpipe |
Broken spring, broken diaphragm |
1.Insufficient air supply after spraying, valve cannot be closed quickly 2.Plunger crooked, diaphragm does not reset properly 3.The coil is energized for a long time, which produces electromagnetic memory |
1. Connect small air bags into a large capacity; Thickened pipe 2. repalce plunger 3. Detect pulse input , repalce solenoid coil |
phenomenon |
Reason |
Solution |
Solenoid coil does not work |
1. Voltage mismatch 2. The solenoid is not powered or burned 3. Plunger Crooked 4. Spring misalignment is stuck |
1. Check if the voltage matches; Replace the pulse control system 2. Repalce solenoid coil 3. Repalace plunger 4. Replace component or reinstall small spring in plunger |
solenoid coil working, but Valve does not blow |
air hole blocked |
Installation cleaning filter |
فئة المنتج : جامع الغبار صمام نبض > نبض النفاث صمام